| The brightest, longest-lasting 110V Step Light |
 |
|
|

Prism Cover
|

Louver Cover
|

Scoop Cover
|
|
APPLICATIONS
- INTERIOR STEPS
- EXTERIOR STEPS
- AISLES
- HALLS
- PATHS
- PATIO LIGHTING
- ENTRY LIGHTING
- POST LIGHTING
- CEILINGS
- SHOWERS
XENON ADVANTAGES
- Less relamping. 10,000-hour average bulb life of Xenon vs. 2,500-hour average bulb life for Halogen or Incandescent.
- Does not emit harmful UV rays.
- Produces less heat.
- Considerably safer due to less pressure in bulb vessel.
- Does not require tempered glass cover.
- Dimmable.
- Handling or dimming bulb does not affect bulb life as in Halogen.
STYLES & OPTIONS
All sold only as complete unit - cover and can.
LOUVER COVER
XSL-L-WH/BZ/AL/BK
White, Bronze, Aluminum, Black
SCOOP COVER
XSL-S-BZ/WH/BK/AL
Bronze, White, Black, Aluminum
PRISM COVER
XSL-P-AL/WH/BZ/BK
Aluminum, White, Bronze, Black
XENON STEP LIGHT PACKAGING
XEN-12-18W
CLEAR REPLACEMENT BULB
|
FEATURES
- UL Listed for wall, IC, ceiling and shower locations
- 3 cover designs: Louver, Prism and Scoop
- 4 cover color options: White, Black, Bronze or Aluminum
- 10,000-hour average bulb life
- 110V Power Input
- Integral 12V class 2 transformer in each fixture
|
- Die cast aluminum can and cover; suitable for concrete pour
- Frosted glass lens
- Bulb replacement has low voltage safety
- 110V push-in connectors included for ease of power input
- Each fixture ships complete with can and cover
|
DIMENSIONS
 |
COVER |
LENGTH |
WIDTH |
DEPTH |
| LOUVER |
7.5" |
4.625" |
.75" |
| PRISM |
7.5" |
4.625" |
.75" |
| SCOOP |
7.5" |
4.625" |
1.5" |
| CAN |
5.5" |
4" |
2.5" |
| HOLE |
5.5" |
4" |
2.5" |
SPECS
| Voltage |
110V power input. Integral Class 2 12V transformer per fixture |
| Bulb Specifications |
18W wedge base Xenon (1 bulb per fixture) |
| Average Bulb Life |
10,000 hours |
| Cover Finish |
White, Black, Bronze, or Aluminum |
| Can Finish |
White with white reflector |
| Packaging |
Individually packaged in 2-color corrugated box |
| Construction |
Both cover and can are die cast aluminum for corrosion protection, strength, weight, and consistency of finish. |
| Lens |
Frosted glass |
| Wiring Options |
110V can be parallel wired ("daisy chained") up to 1188 watts (66 bulbs). One wire between each fixture completes chain. No custom cord required. Check local code and NEC for wiring selection. |
| Agency Approval |
UL listed and labeled wet and IC locations, including walls, showers and ceilings |
FLOOR PHOTOMETRICS
| Grid Location: |
A |
A1 |
A2 |
B |
B1 |
B2 |
C |
C1 |
C2 |
D |
D1 |
D2 |
| Illuminance in Footcandles: |
0 |
0 |
0 |
8.1 |
2.3 |
0.4 |
3.5 |
2.0 |
0.6 |
1.3 |
1.0 |
0.5 |
XENON BULBS
CONCRETE CAP - DIRECT POUR MOUNTING ACCESSORY!

SL-CC
Step Light Concrete Cap |

Concrete Cap
installed in fixture
|
|

Assembly Schematic |
|
|